Welcome To Future Industrial Instruments Co., Ltd.
Endress+Hauser differential pressure transmitter
PRODUCTS
Contact Us
LatestProducts
  • total dissolved solids meter  Proline Teqwave MW 500 – Total solids meter
  • KROHNE wastewater applications
  • Pressure switch for hygienic level and pressure applications
  • KROHNE  Pressure transmitter for hygienic pressure and level applications
  • KROHNE Pressure switch for basic pressure and level applications
  • Pressure transmitter for basic pressure and level applications
Endress+Hauser Electronic differential pressure Deltabar FMD72
  • Endress+Hauser Electronic differential pressure Deltabar FMD72
  • Endress+Hauser Electronic differential pressure Deltabar FMD72
  • Endress+Hauser Electronic differential pressure Deltabar FMD72

Endress+Hauser Electronic differential pressure Deltabar FMD72

Electronic differential pressure system utilizing two metal sensor modules and one transmitter ……

Description

Electronic differential pressure system utilizing two metal sensor modules and one transmitter


Specs at a glance

  • Accuracy

    0.075% of individual sensor,
    “PLATINUM” 0.05% of individual sensor

  • Process temperature

    –40…+125°C
    (–40 … +257°F)

  • Pressure measuring range

    400 mbar…10 bar
    (6 psi…150 psi)

  • Process pressure / max. overpressure limit

    160 bar (2400 psi)

  • Main wetted parts

    316L, Alloy C

  • Material process membrane

    316L, AlloyC,

  • Measuring cell

    400 mbar…10 bar
    (6 psi…150psi)

Field of application

The Deltabar FMD72 is an electronic differential pressure system used to measure pressure, level, volume, or mass of liquids in pressurized tanks or distillation columns/evaporators. The high pressure sensor (HP) measures the hydrostatic pressure, while the low pressure sensor (LP) measures the head pressure. The level is then calculated in the transmitter using these two digital values. This electronic differential pressure system eliminates the issues associated with traditional differential pressure measurements.

For differential pressure, level, volume or mass measurement of liquids in pressurized tanks and distillation columns/evaporators.

  • Process connections: Threads, flanges and hygienic connections

  • Process temperature: -40 to +125°C (-40 to +257°F), optional 250°C (480°F)

  • Measuring range: 400mbar to +40bar (6 to 600psi)

  • Accuracy: Single sensor up to ±0.05%, system up to ±0.07%

  • International explosion protection certificates, hygienic approvals

Benefits

  • Eliminates traditional mechanical issues resulting in greater process availability and reliability

  • Safety risks are minimized with the new electronic differential pressure system architecture and design

  • Lowest total cost of ownership due to reduced installation time, maintenance, downtime and spare requirements

  • Multivariable level measurement: HART-based differential pressure, head pressure and sensor temperatures from one system

  • Continuous health indication of the entire system via HART-based diagnostic

  • High reproducibility and long-term stability

  • Process safety assured with small flush mounted process connections in hygienic applications

    Specifications

    • Characteristic

      Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.

    • Supply voltage

      4…20 mA HART:
      12…45V DC (Non Ex)
      Ex ia: 12…30V DC

    • Reference Accuracy

      0.075% of individual sensor,
      “PLATINUM” 0.05% of individual sensor

    • Long term stability

      0.05% of URL/year of individual sensor

    • Process temperature

      –40…+125°C
      (–40…+257°F)

    • Ambient temperature

      –40…+80°C
      (–40…+176°F)

    • Measuring cell

      400 mbar…10 bar
      (6 psi…150psi)

    • Vacuum resistance

      10 mbar (0.15 psi)

    • Max. overpressure limit

      160 bar (2400 psi)

    • Process connection

      Threads
      Flange (DIN, ASME,JIS)

    • Process connection hygienic

      DIN11851
      DIN11864-1
      Tri-Clamp
      DRD
      Varivent

    • Material process membrane

      316L, AlloyC,

    • Fill fluid

      Silicone oil
      Synthetic oil

    • Material housing

      Die-cast aluminum
      Stainless steel

    • Communication

      4…20 mA HART

    • Certificates / Approvals

      ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex

    • Design approvals

      NACE MR0175,
      EN10204-3.1,

    • Hygienic approvals

      EHEDG
      3A

x